 PHYSICAL PROPERTIES  | 
|
| 
 PROPERTY  | 
 RESULT  | 
| 
 Color  | 
 White  | 
| 
 Thickness  | 
 10.2 mil (0.26 mm)  | 
| 
 Membrane Weight  | 
 0.95 oz/yd² (289 g/m²)  | 
| 
 60" Roll Weight  | 
41 lbs (18.6 kg) | 
| 
 60" Roll Weight  | 
 39 lbs (17.7 kg)  | 
| 
 30" Roll Weight  | 
 21 lbs (9.5 kg)  | 
| 
 30" Roll Weight  | 
19 lbs (8.6 kg) | 
| 
 Roll Dimensions  | 
 60" x 100' (1.5 m x 30.5 m)  | 
| 
 Roll Coverage  | 
 60" 500 ft² (46.5 m²) gross  | 
| 
 Primer  | 
 No Primer Required  | 
| 
 VOCs  | 
 None  | 
| 
 Field Exposure Before Roof/Cladding Materials  | 
 Roofs: 180 days  | 
| 
 Minimum Application Temperature  | 
 20°F (-6.6°C) and rising  | 
| 
 Service Temperature  | 
 minus 40°F (-40°C) - 270°F (132.2°C)  | 
| 
 Warranty  | 
 20 year material warranty  | 
| 
 TESTING DATA  | 
||
| 
 PROPERTY  | 
 STANDARD  | 
 RESULT  | 
| 
 Strength  | 
||
| 
 Elongation  | 
 ASTM D412 Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers—Tension  | 
 MD - 409%  | 
| 
 Tensile Strength  | 
 ASTM D412 Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers—Tension  | 
 MD - 16.96 MPa (2460 psi)   | 
| 
 Dry Tensile Strength  | 
 ASTM D882 Standard Test Method for Tensile Properties of Thin Plastic Sheeting  | 
 MD - 3.85 N/mm (22 lbf/in)  | 
| 
 Elongation at Break  | 
 ASTM D882 Standard Test Method for Tensile Properties of Thin Plastic Sheeting  | 
 MD - 541%   | 
| 
 Dry Breaking Force (Grab method) MD ≥40 XMD ≥35  | 
 ASTM D5034 Standard Test Method for Breaking Strength and Elongation of Textile Fabrics (Grab Test)  | 
 MD – 338 N (76 lbsf)  | 
| 
 Elongation at Break  | 
 ASTM D5034 Standard Test Method for Breaking Strength and Elongation of Textile Fabrics (Grab Test)  | 
 MD - 120%   | 
| 
 Minimum Puncture Resistance  | 
 ASTM E154 Standard Test Methods for Water Vapor Retarders Used in Contact with Earth Under Concrete Slabs, on Walls, or as Ground Cover  | 
 Deflection 5.84 cm (2.3")   | 
| 
 Cold Mandrel Bend Test  | 
 AC38 Section 3.3.4  | 
 PASS  | 
| 
 Weathering Tests  | 
 AC38 Section 4.1.2 UV Exposure  | 
 PASS  | 
| Wear Resistance | Wheelbarrow Testing | PASS | 
| Self Adhering Flashing | AAMA 711-13 Voluntary Specification for Self Adhering Flashing Used for Installation of Exterior Wall Fenestration Products | Compliant | 
| 
 Water Vapor Transmittance  | 
||
| 
 Water Vapor Transmission Desiccant Method Procedure A 23°C (73.4°F) 0-50 %RH  | 
 ASTM E96 Standard Test Methods for Water Vapor Transmission of Materials  | 
 0.0173 Perm (grain/h•ft²•inchHg) @23°C 100%RH   | 
| 
 Water Vapor Transmission Using Modulated Infrared Sensor  | 
 ASTM F1249 Standard Test Method for Water Vapor Transmission Rate Through Plastic Film and Sheeting Using a Modulated Infrared Sensor  | 
 0.0193 Perm (grain/h•ft2•inchHg) 1.10 ng/Pa•s•m2  | 
| Water Ponding | ICC-ES AC48 Acceptance Criteria for Self-Adhered Roof Underlayments for use as IBarriers | PASS | 
| 
 Air Resistance Testing  | 
||
| 
 Air Permeance  | 
 ASTM E2178 @75 Pa Standard Test Method for Air Permeance of Building Materials  | 
 0.00912 L/s•m² @ 75 Pa (0.0018 cfm/ft² @ 1.57 psf)  | 
| 
 Air Permeance  | 
 CAN/ULC-S741-08 (2020) Standard for Air Barrier Materials  | 
 PASS  | 
| 
 Air Leakage Rate  | 
 CAN/ULC-S742-11 Standard for Air Barrier Assemblies  | 
Class A1
 
  | 
| 
 Water Resistance Testing  | 
||
| 
 Nail Sealability  | 
 ASTM D1970 Standard Specification for Self-Adhering Polymer Modified Bituminous Sheet Materials Used as Steep Roofing Underlayment for Ice Dam Protection Section 7.9 referring to ASTM D7349 protocol 4 with modifications  | 
 PASS  | 
| 
 Water Resistance (Control after Weathering)  | 
 AATCC 127 Hydrostatic pressure test (550 mm water column for 5 hours), American Association of Textile Chemists and Colorists  | 
 PASS  | 
| 
 Fire Testing  | 
||
| 
 Flame Spread Smoke Developed  | 
 ASTM E84 Standard Test Method for Surface Burning Characteristics of Building Materials  | 
 Flame Spread 5 (Class A)  | 
| 
 UL  | 
 UL790 Test Method of Fire Tests for Roof Coverings, CAN/ULC-S107  | 
 PASS  | 
| Surface Burning Characteristics | CAN/ULC-S102 Protective Underlayment, Permeable to Allow Drying, Provides an Air Barrier | Flame Spread Rating: 5 Smoke Developed Value: 15  | 
 ![]()  | 
![]()  | 
    
            
						
 