pdf Printer Friendly (PDF) (1.85 MB)
| PHYSICAL PROPERTIES | |
| PROPERTY | RESULT |
|
Color |
Black/Yellow |
|
Thickness |
14 mil (0.36 mm) |
|
Membrane Weight |
275.7 g/m2 (0.904 oz/ft2) |
|
Roll Weight (with release film) |
40 lbs (18 kg) |
|
Roll Dimensions |
59” x 102’ (1.5m x 31m) |
|
Roll Coverage |
500 ft2 (46.65 m2) |
|
Skid |
25 Rolls |
|
Primer |
No Primer Required |
|
VOCs |
None |
|
Field Exposure Before Permanent Cladding |
12 months |
|
Minimum Application Temperature |
20° F (-6°C) |
|
Service Temperature |
Minus 40°F (-40°C) - 250°F (121°C) |
|
Warranty |
20 year material warranty |
| TESTING DATA | ||
| PROPERTY | STANDARD | RESULT |
|
Strength |
||
|
Dry Breaking Force (Grab method) MD ≥40 XMD ≥35 |
ASTM D5034 Standard Test Method for Breaking Strength and Elongation of Textile Fabrics (Grab Test) |
MD - 560 N (126 lbf) |
|
Dry Breaking Force (Grab method) MD ≥40 XMD ≥35 |
ASTM D5034 Standard Test Method for Breaking Strength and Elongation of Textile Fabrics (Grab Test) |
MD - 529 N (119 lbf) |
|
Cold Mandrel Bend Test |
AC38 Section 3.3.4 |
MD – no cracks Pass |
|
Weathering Tests |
AC38 Section 4.1.2 UV Exposure |
Accelerated UV aging: No objectionable appearance Thermal Cycling: No objectionable appearance Elevated Temperature: No objectionable appearance Water immersion: No objectionable appearance |
|
Water Vapor Transmittance |
||
|
Water Vapor Transmission Desiccant Method Procedure A |
ASTM E96 Standard Test Methods for Water Vapor Transmission of Materials |
8.86 Perm (grain/h•ft²•inchHg) |
| Water Vapor Transmission Water Method Procedure B | ASTM E96 Standard Test Methods for Water Vapor Transmission of Materials | 24.3 Perm (grain/h•ft²•inchHg) 1390 ng/Pa•s•m² (23°C 50-100 %RH) |
| Water Vapor Transmission Using Modulated Infrared Sensor | ASTM F1249 Standard Test Method for Water Vapor Transmission Rate Through Plastic Film and Sheeting Using a Modulated Infrared Sensor | 5.9 Perm (grain/h•ft²•inchHg) 338 ng/Pa•s•m² (23°C 0-50 %RH) |
|
Adhesion Testing |
||
|
Lap Peel Strength |
ASTM D1876 Standard Test Method for Peel Resistance of Adhesives (T-Peel Test) |
2.0 lbf/in (0.35 N/mm) |
| Adhesion to backing 180° Peel Adhesion | ASTM D3330 method B | 3.2 lbf/in (0.56 N/mm) |
| 90° Peel Adhesion | AAMA 711 Section 5.3 (ASTM D3330 method F PASS ≥ 0.26 N/mm (1.5 lbs/in) | Anodized aluminum 2.7 lbf/inch (0.47 N/mm) DensGlass Gold 3.0 lbf/inch (0.53 N/mm) OSB 1.5 lbf/inch (0.26 N/mm) Plywood 2.7 lbf/inch (0.47 N/mm) Vinyl 2.3 lbf/inch (0.40 N/mm) Facing material 1.7 lbf/inch (0.30 N/mm) |
| Accelerated Aging and UV exposure 90° Peel Adhesion 24 hours | AAMA 711 Section 5.4 |
Accelerated UV aging 3.1 lbf/inch (0.54 N/mm) |
| Elevated Temperature (80 °C for 7 days) 90° Peel Adhesion 24 hours | AAMA 711 Section 5.5 |
Elevated Temp 176°F (80°C) 1.8 lbf/inch (0.32 N/mm) |
| Thermal Cycling 90° Peel Adhesion 24 hours | AAMA 711 Section 5.6 |
Thermal Cycling 2.7 lbf/inch (0.47 N/mm) |
| Adhesion after Water Immersion | AAMA 711 Section 5.8 |
Water immersion 2.2 lbf/inch (0.39 N/mm) |
| Resistance to Peeling from Itself 90° Peel Adhesion 24 hours |
AAMA 711 Section 5.9 & Annex A |
Pass level 3 |
| Pull Adhesion | ASTM 4541 | Glass-fiber faced gypsum 33 psi (0.23 MPa) CMU Block 28 psi (0.19 MPa) |
|
Air Resistance Testing |
||
|
Air Permeance |
ASTM E2178 @75 Pa Standard Test Method for Air Permeance of Building Materials |
0.0017 L/s•m² @ 75 Pa (<0.000335 cfm/ft² @ 1.57 psf) |
|
Air Barrier |
ASTM E2357 Standard Test Method for Determining Air Leakage of Air Barrier Assemblies |
<0.0086 L/s•m² @ 75 Pa (<0.0017 cfm/ft² @ 1.57 psf) |
|
Air Barrier |
CAN/ULC-S742-11-R2016 exterior side of the assembly is cooled to -20 °C while the interior |
A1 Classification: |
| Air Barrier | CAN/ULC-S741-08 air leakage cannot exceed 0.05 L/s•m² @ 75 Pa. Air leakage rate of the air barrier material after conditioning must not be more than 10% or 0.001 L/s•m² greater than its air leakage before conditioning | Value: Meets requirements Unconditoned < 0.02 L/s•m² at 75 Pa (0.00394 cfm/ft² @ 1.57 psf) Conditioned <0.01 L/s•m² at 75 Pa (0.00197 cfm/ft² @ 1.57 psf) |
|
Water Resistance Testing |
||
|
Water Resistance |
AATCC 127 Hydrostatic pressure test (55 cm water column for 5 hours), American Association of Textile Chemists and Colorists |
Control - No leakage |
|
Fire Testing |
||
|
Flame Spread Smoke Developed |
ASTM E84 Standard Test Method for Surface Burning Characteristics of Building Materials |
Flame Spread 0 Smoke Developed 0 |
| ASTM E1354 | ASTM E1354 Standard Test Method for Heat and Visible Smoke Release Rates for Materials and Products Using an Oxygen Consumption Calorimeter |
Ave. Effective Heat of Combustion: 1.4 MJ/kg |
| Surface Burning Characteristics | CAN/ULC-S102 Standard Method of Test for Surface Burning Characteristics of Building Materials and Assemblies | Flame Spread 5 Smoke Developed 10 |