PHYSICAL PROPERTIES
PROPERTY RESULT

Color

Black/Yellow

Thickness

14 mil (0.36 mm)

Membrane Weight

275.7 g/m2 (0.904 oz/ft2)

Roll Weight (with release film)

40 lbs (18 kg)

Roll Dimensions

59” x 102’ (1.5m x 31m)

Roll Coverage

500 ft2 (46.65 m2)

Skid

25 Rolls

Primer

No Primer Required

VOCs

None

Field Exposure Before

Permanent Cladding

12 months

Minimum Application

Temperature

20° F (-6°C)

Service Temperature

Minus 40°F (-40°C) - 250°F (121°C)

Warranty

20 year material warranty

 

TESTING DATA
PROPERTY STANDARD RESULT

Strength

Dry Breaking Force (Grab method) MD ≥40 XMD ≥35

ASTM D5034 Standard Test Method for Breaking Strength and Elongation of Textile Fabrics (Grab Test)

MD - 560 N (126 lbf)
XMD - 378 N (85 lbf)

Dry Breaking Force (Grab method) MD ≥40 XMD ≥35

ASTM D5034 Standard Test Method for Breaking Strength and Elongation of Textile Fabrics (Grab Test)

MD - 529 N (119 lbf)
XMD - 427 N (96 lbf)

Cold Mandrel Bend Test

AC38 Section 3.3.4

MD – no cracks Pass
XCD – no cracks Pass

Weathering Tests

AC38 Section 4.1.2 UV Exposure
AC38 Section 4.1.3 Accelerated Aging

Accelerated UV aging: No objectionable appearance Thermal Cycling: No objectionable appearance Elevated Temperature: No objectionable appearance Water immersion: No objectionable appearance

Water Vapor Transmittance

Water Vapor Transmission Desiccant Method Procedure A

ASTM E96 Standard Test Methods for Water Vapor Transmission of Materials

8.86 Perm (grain/h•ft²•inchHg)
507 ng/Pa•s•m²
(23°C 50-100 %RH)

Water Vapor Transmission Water Method Procedure B ASTM E96 Standard Test Methods for Water Vapor Transmission of Materials 24.3 Perm (grain/h•ft²•inchHg)
1390 ng/Pa•s•m²
(23°C 50-100 %RH)
Water Vapor Transmission Using Modulated Infrared Sensor ASTM F1249 Standard Test Method for Water Vapor Transmission Rate Through Plastic Film and Sheeting Using a Modulated Infrared Sensor 5.9 Perm (grain/h•ft²•inchHg)
338 ng/Pa•s•m²
(23°C 0-50 %RH)

Adhesion Testing

Lap Peel Strength

ASTM D1876 Standard Test Method for Peel Resistance of Adhesives (T-Peel Test)

2.0 lbf/in (0.35 N/mm)

Adhesion to backing 180° Peel Adhesion ASTM D3330 method B 3.2 lbf/in (0.56 N/mm)
90° Peel Adhesion AAMA 711 Section 5.3 (ASTM D3330 method F PASS ≥ 0.26 N/mm (1.5 lbs/in) Anodized aluminum 2.7 lbf/inch (0.47 N/mm)
DensGlass Gold 3.0 lbf/inch (0.53 N/mm)
OSB 1.5 lbf/inch (0.26 N/mm)
Plywood 2.7 lbf/inch (0.47 N/mm)
Vinyl 2.3 lbf/inch (0.40 N/mm)
Facing material 1.7 lbf/inch (0.30 N/mm)
Accelerated Aging and UV exposure 90° Peel Adhesion 24 hours AAMA 711
Section 5.4
Accelerated UV aging 3.1 lbf/inch (0.54 N/mm)
Elevated Temperature (80 °C for 7 days) 90° Peel Adhesion 24 hours AAMA 711
Section 5.5
Elevated Temp 176°F (80°C) 1.8 lbf/inch (0.32 N/mm)
Thermal Cycling 90° Peel Adhesion 24 hours AAMA 711
Section 5.6
Thermal Cycling 2.7 lbf/inch (0.47 N/mm)
Adhesion after Water Immersion AAMA 711
Section 5.8
Water immersion 2.2 lbf/inch (0.39 N/mm)
Resistance to Peeling from Itself 90°
Peel Adhesion 24 hours
AAMA 711
Section 5.9 & Annex A
Pass level 3
Pull Adhesion ASTM 4541 Glass-fiber faced gypsum 33 psi (0.23 MPa)
CMU Block 28 psi (0.19 MPa)

Air Resistance Testing

Air Permeance

ASTM E2178 @75 Pa Standard Test Method for Air Permeance of Building Materials

0.0017 L/s•m² @ 75 Pa (<0.000335 cfm/ft² @ 1.57 psf)

Air Barrier

ASTM E2357 Standard Test Method for Determining Air Leakage of Air Barrier Assemblies

<0.0086 L/s•m² @ 75 Pa (<0.0017 cfm/ft² @ 1.57 psf)

Air Barrier

CAN/ULC-S742-11-R2016 exterior side of the assembly is cooled to -20 °C while the interior
side is maintained at 20 °C air leakage cannot exceed 0.05 L/s•m² @ 75 Pa

A1 Classification:
< 0.05 L/s•m² at 75 Pa (.0098 cfm/ft² @ 1.57 psf)

Air Barrier CAN/ULC-S741-08 air leakage cannot exceed 0.05 L/s•m² @ 75 Pa. Air leakage rate of the air barrier material after conditioning must not be more than 10% or 0.001 L/s•m² greater than its air leakage before conditioning Value:
Meets requirements
Unconditoned < 0.02 L/s•m² at 75 Pa
(0.00394 cfm/ft² @ 1.57 psf)
Conditioned <0.01 L/s•m² at 75 Pa
(0.00197 cfm/ft² @ 1.57 psf)

Water Resistance Testing

Water Resistance
(Control after Weathering)

AATCC 127 Hydrostatic pressure test (55 cm water column for 5 hours), American Association of Textile Chemists and Colorists

Control - No leakage
Weathered - No Leakage

Fire Testing

Flame Spread Smoke Developed

ASTM E84 Standard Test Method for Surface Burning Characteristics of Building Materials

Flame Spread 0 Smoke Developed 0

ASTM E1354 ASTM E1354 Standard Test Method for Heat and Visible Smoke Release Rates for Materials and Products Using an Oxygen Consumption Calorimeter

Ave. Effective Heat of Combustion: 1.4 MJ/kg
Peak HRR: 35 kW/m²
Total HRR/A: 1.6 MJ/m²

Surface Burning Characteristics CAN/ULC-S102 Standard Method of Test for Surface Burning Characteristics of Building Materials and Assemblies Flame Spread 5 Smoke Developed 10