| PHYSICAL PROPERTIES | |
| PROPERTY | RESULT | 
| 
 Color  | 
 Black/Yellow  | 
| 
 Thickness  | 
 0.37 mm (15 mil)  | 
| 
 Membrane Weight  | 
 275.7 g/m2 (0.904 oz/ft2)  | 
| 
 Roll Weight (with release film)  | 
 40 lbs (18 kg)  | 
| 
 Roll Dimensions  | 
 59” x 102’ (1.5m x 31m)  | 
| 
 Roll Coverage  | 
 500 ft2 (46.65 m2)  | 
| 
 Skid  | 
 25 Rolls  | 
| 
 Primer  | 
 No Primer Required  | 
| 
 VOCs  | 
 None  | 
| 
 Field Exposure Before Permanent Cladding  | 
 12 months  | 
| 
 Minimum Application Temperature  | 
 20° F (-6°C)  | 
| 
 Service Temperature  | 
 Minus 40°F (-40°C) - 250°F (121°C)  | 
| 
 Warranty  | 
 20 year material warranty  | 
| TESTING DATA | ||
| PROPERTY | STANDARD | RESULT | 
| 
 Strength  | 
||
| 
 Dry Tensile Strength ≥ 20 lbs/in  | 
 ASTM D828 Standard Test Method for Tensile Properties of Paper and Paperboard Using Constant-Rate-of-Elongation Apparatus  | 
 MD – 6.6 N/mm (37.7 ibs/in)  | 
| 
 Dry Breaking Force (Grab method) MD ≥40 XMD ≥35  | 
 ASTM D5034 Standard Test Method for Breaking Strength and Elongation of Textile Fabrics (Grab Test)  | 
 MD – 529 N (119 lbsf) CD – 427 N (96 lbsf)  | 
| 
 Cold Mandrel Bend Test  | 
 AC38 Section 3.3.4  | 
 Warp (Machine) Direction - No cracking   | 
| 
 Weathering Tests  | 
 AC38 Section 4.1.2 UV Exposure   | 
 UV - No visual change   | 
| 
 Water Vapor Transmittance  | 
||
| 
 Water Vapor Transmission Dynamic Relative Humidity Measurement (23°C 50 %RH)  | 
 ASTM E398 Standard Test Method for Water Vapor Transmission Rate of Sheet Materials Using Dynamic Relative Humidity Measurement  | 
 26.02 Perm (grain/h•ft2•inchHg) 1489 ng/Pa•s•m2  | 
| 
 Adhesion Testing  | 
||
| 
 90˚ Peel Adhesion  | 
 AAMA 711  | 
 PASS  | 
| 
 Air Resistance Testing  | 
||
| 
 Air Permeance  | 
 ASTM E2178 @75 Pa Standard Test Method for Air Permeance of Building Materials  | 
 0.0001 L/s•m2 @ 75 Pa (0.0000 cfm/ft2 @ 1.57 psf)  | 
| 
 Air Barrier  | 
 ASTM E2357 Standard Test Method for Determining Air Leakage of Air Barrier Assemblies  | 
 <0.01 L/s•m2 @ 75 Pa (<0.002 cfm/ft2 @ 1.57 psf)  | 
| 
 Air Barrier  | 
 ASTM E283 Standard Test Method for Determining Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors Under Specified Pressure Differences Across the Specimen  | 
 <0.01 L/s•m2 @ 75 Pa (<0.01 cfm/ft2 @ 1.57 psf)  | 
| 
 Water Resistance Testing  | 
||
| 
 Nail Sealability  | 
 ASTM D1970/ section 7.9 Standard Specification for Self-Adhering Polymer Modified Bituminous Sheet Materials Used as Steep Roofing Underlayment for Ice Dam Protection  | 
 Pass - Review Fastener Penetrations Technical Bulletin  | 
| 
 Water Resistance (Boat Test)  | 
 ASTM D779 Standard Test Method for Water Resistance of Paper, Paperboard, and Other Sheet Materials by the Dry Indicator Method (Withdrawn 2011)  | 
 Control - No leakage Weathered - No Leakage  | 
| 
 Water Resistance (Control after Weathering)  | 
 AATCC 127 Hydrostatic pressure test (550 mm water column for 5 hours), American Association of Textile Chemists and Colorists  | 
 Control - No leakage Weathered - No Leakage  | 
| 
 Fire Testing  | 
||
| 
 Flame Spread Smoke Developed  | 
 ASTM E84 Standard Test Method for Surface Burning Characteristics of Building Materials  | 
 Flame Spread 0 Smoke Developed 20  | 
| Cone Calorimeter Testing Data | ASTM E1354 Standard Test Method for Heat and Visible Smoke Release Rates for Materials and Products Using an Oxygen Consumption Calorimeter | 
 Time to ignition: 7 sec  | 
    
            