 PHYSICAL PROPERTIES  | 
|
| 
 PROPERTY  | 
 RESULT  | 
| 
 Color  | 
 Red  | 
| 
 Thickness  | 
 0.75mm (30 mil)  | 
| 
 Membrane Weight  | 
 249.6 g/m² (0.818oz/ft²)  | 
| 
 Roll Weight (with release film)  | 
 25.9 kg (57.2 lbs)  | 
| 
 Roll Dimensions  | 
 1.5m x 50m (59" x 164')  | 
| 
 Roll Coverage  | 
 75m² (807 ft²)  | 
| 
 Skid  | 
 16 rolls  | 
| 
 Primer  | 
 No Primer Required  | 
| 
 VOCs  | 
 None  | 
| 
 Field Exposure Before Permanent Cladding  | 
 6 months, 180 days  | 
| 
 Minimum Application Temperature  | 
 -6.6°C (20° F) and rising  | 
| 
 Service Temperature  | 
 -40°C (40°F) 121°C (250°F)  | 
| 
 Warranty  | 
 20 year material warranty  | 
| 
 TESTING DATA  | 
||
| 
 PROPERTY  | 
 STANDARD  | 
 RESULT  | 
| 
 Strength  | 
||
| 
 Dry Tensile Strength ≥ 20 lbf/in  | 
 ASTM D828 Standard Test Method for Tensile Properties of Paper and Paperboard Using Constant-Rate-of-Elongation Apparatus  | 
 6.1 N/mm(34.8 lbf)  | 
| 
 Dry Breaking Force (Grab method) MD ≥40 XMD ≥35  | 
 ASTM D5034 Standard Test Method for Breaking Strength and Elongation of Textile Fabrics (Grab Test)  | 
 MD - 391 N (88 lbf) XMD - 369 N (83 lbf)  | 
| 
 Cold Mandrel Bend Test  | 
 AC38 Section 3.3.4  | 
 Warp (Machine) Direction - No cracking Filling (Cross) Direction - No cracking  | 
| 
 Weathering Tests  | 
 AC38 Section 4.1.2 UV Exposure AC38 Section 4.1.3 Accelerated Aging  | 
 UV - No visual change UV & Accelerated - visibly lighter, no visible deterioration  | 
| 
 Water Vapor Transmittance  | 
||
| 
 Water Vapor Transmission Desiccant Method, Procedure A, 24.4°C (76.0°F) 50 %RH  | 
 ASTM E96 Standard Test Methods for Water Vapour Transmission of Materials  | 
 8.5 Perm (grain/h•ft2•inchHg) 486 ng/Pa•s•m2  | 
| 
 Water Vapour Transmission Water Method, Procedure B, 24.4°C (76.0°F) 50 %RH  | 
 ASTM E96 Standard Test Methods for Water Vapour Transmission of Materials  | 
 24 Perm (grains/hr•ft2•inchHg) 1373 ng/Pa•s•m2  | 
| 
 Water Vapour Transmission Dynamic Relative Humidity Measurement (23°C 50 %RH)  | 
 ASTM E398 Standard Test Method for Water Vapour Transmission Rate of Sheet Materials Using Dynamic Relative Humidity Measurement  | 
 20.47 Perm (grain/h•ft2•inchHg)  | 
| 
 Air Resistance Testing  | 
||
| 
 Air Permeance  | 
 ASTM E2178 @75 Pa Standard Test Method for Air Permeance of Building Materials  | 
 0.0014 L/s m² @ 75 Pa (0.000276 cfm/ft² @ 1.57 psf )  | 
| Air Barrier | ASTM E2357 Standard Test Method for Determining Air Leakage of Air Barrier Assemblies | 0.0194 L/(s·m²) at 75 Pa (0.0039 cfm/ft² @ 1.57 psf) | 
| Air Permeance | CAN/ULC-S741-08 (2020) Standard for Air Barrier Materials | PASS | 
| Air Leakage Rate | CAN/ULC-S742-11 Standard for Air Barrier Assemblies | Class A1 | 
| 
 Adhesion Testing  | 
||
| 
 Peel Adhesion  | 
 AAMA 711  | 
 PASS  | 
| 
 Water Resistance Testing  | 
||
| 
 Nail Sealability  | 
 ASTM D1970/ section 7.9 Standard Specification for Self-Adhering Polymer Modified Bituminous Sheet Materials Used as Steep Roofing Underlayment for Ice Dam Protection  | 
|
| 
 Water Resistance (Boat Test)  | 
 ASTM D779 Standard Test Method for Water Resistance of Paper, Paperboard, and Other Sheet Materials by the Dry Indicator Method (Withdrawn 2011)  | 
 Control - No leakage   | 
| 
 Water Resistance (Control after Weathering)  | 
 AATCC 127 Hydrostatic pressure test (550 mm water column for 5 hours), American Association of Textile Chemists and Colourists  | 
 Control - No leakage   | 
| 
 Fire Testing  | 
||
| 
 Flame Spread Smoke Developed  | 
 ASTM E84 Standard Test Method for Surface Burning Characteristics of Building Materials  | 
 Flame Spread 10 Smoke Developed 10  | 
| Surface Burning Characteristics | CAN/ULC-S102 Protective underlayment, Permeable to allow drying, Provides an Air Barrier | Flame Spread Rating: 5 Smoke Developed Value: 20  | 
    
            