pdf Product Data Sheet (PDF) (3.51 MB)
| 
 PHYSICAL PROPERTIES  | 
||
| 
 PROPERTY  | 
 WrapShield RS 3mm  | 
 WrapShield RS 7mm  | 
| 
 Color  | 
 Beige Membrane/Black Matrix  | 
|
| 
 Thickness with Matrix  | 
 4.4 mm  | 
 7.2 mm  | 
| 
 Membrane Weight with Matrix  | 
 504.4 g/m² (1.7 oz/ft²)  | 
 580.1 g/m² (1.9 oz/ft²)  | 
| 
 Roll Weight  | 
 27lbs (12kg)  | 
 27lbs (12kg)  | 
| 
 Roll Dimensions gross  | 
 29.5 x 105’ (.75m x 32m), 258.1 S/F (23.9 S/M)  | 
 29.5" x 60' (.75m x 18.2m) 147.5 S/F (13.7 S/M)  | 
| 
 Roll Dimensions Net  | 
 26.5” x 105’ (0.7m x 32m), 231.9 S/F (21.5 S/M)  | 
 26.5" x 60' (.7m x 18.2m), 132.5 S/F (12 S/M)  | 
| 
 Skid  | 
 15 Rolls  | 
|
| 
 Primer  | 
 No Primer Required  | 
|
| 
 VOCs  | 
 None  | 
|
| 
 Exposure Before Permanent Cladding  | 
 90 days  | 
|
| 
 Minimum Application Temperature  | 
 20°F (-6°C)  | 
|
| 
 Service Temperature  | 
 -40°F (-40°C) to 225°F (107°C)  | 
|
| 
 Warranty  | 
 20 year material warranty  | 
|
| 
 TESTING DATA  | 
||
| 
 PROPERTY  | 
 STANDARD  | 
 RESULT  | 
| 
 Strength  | 
||
| 
 Dry Tensile Strength ≥ 20 lbs/in  | 
 ASTM D828 Standard Test Method for Tensile Properties of Paper and Paperboard Using Constant-Rate-of-Elongation Apparatus  | 
 MD - 6.1 N/mm (34.8 lbs/in)  | 
| 
 Dry Breaking Force (Grab method) MD ≥40 XMD ≥35  | 
 ASTM D5034 Standard Test Method for Breaking Strength and Elongation of Textile Fabrics (Grab Test)  | 
 MD – 391 N (88 lbf) CD – 369 N (83 lbf)  | 
| 
 Cold Mandrel Bend Test  | 
 AC38 Section 3.3.4  | 
 Warp (Machine) Direction - No cracking Filling (Cross) Direction - No cracking  | 
| 
 Weathering Tests  | 
 AC38 Section 4.1.2 UV Exposure AC38 Section 4.1.3 Accelerated Aging  | 
 UV - No visual change UV & Accelerated - visibly lighter, no visible deterioration  | 
| 
 Water Vapor Transmittance  | 
||
| 
 Water Vapor Transmission Desiccant Method, Procedure A, 24.4°C (76.0°F) 50 %RH  | 
 ASTM E96 Standard Test Methods for Water Vapor Transmission of Materials  | 
 14.7 Perm (grain/h•ft2•inchHg) 480 ng/Pa•s•m2  | 
| 
 Water Vapor Transmission Water Method, Procedure B, 24.4°C (76.0°F) 50 %RH  | 
 ASTM E96 Standard Test Methods for Water Vapor Transmission of Materials  | 
 20.5 Perm (grains/hr•ft2•inchHg) 1171 ng/Pa•s•m2  | 
| 
 Water Vapor Transmission  | 
 ASTM E398 Standard Test Method for Water Vapor Transmission Rate of Sheet Materials Using Dynamic Relative Humidity Measurement  | 
 21.95 Perm (grain/h•ft2•inchHg) 1255 ng/Pa•s•m2  | 
| 
 Air Resistance Testing  | 
||
| 
 Air Permeance  | 
 ASTM E2178 @75 Pa Standard Test Method for Air Permeance of Building Materials  | 
 0.0014 L/s m² @ 75 Pa (0.00276 cfm/ft² @ 1.57 psf)  | 
| 
 Adhesion Testing  | 
||
| 
 90° Peel Adhesion  | 
 AAMA 711  | 
 PASS  | 
| 
 Water Resistance Testing  | 
||
| 
 Nail Sealability  | 
 ASTM D1970/ section 7.9 Standard Specification for Self-Adhering Polymer Modified Bituminous Sheet Materials Used as Steep Roofing Underlayment for Ice Dam Protection  | 
 Pass - pdf Review Fastener Penetrations Technical Bulletin (2.20 MB)  | 
| 
 Water Resistance (Boat Test)  | 
 ASTM D779 Standard Test Method for Water Resistance of Paper, Paperboard, and Other Sheet Materials by the Dry Indicator Method (Withdrawn 2011)  | 
 Control - No leakage Weathered - No Leakage  | 
| 
 Water Resistance (Control after Weathering)  | 
 AATCC 127 Hydrostatic pressure test (550 mm water column for 5 hours), American Association of Textile Chemists and Colorists  | 
 Control - No leakage Weathered - No Leakage  | 
| Drainage Test | ASTM E2273 Standard Test Method for Determining the Drainage Efficiency of Exterior Insulation and Finish Systems (EIFS) Clad Wall Assemblies | Exceeds Required 90% | 
| 
 Fire Testing  | 
||
| 
 Flame Spread Smoke Developed  | 
 ASTM E84 Standard Test Method for Surface Burning Characteristics of Building Materials  | 
 Flame Spread 10 Smoke Developed 75 (Class A)  | 
    
            