pdf
Product Data Sheet
(1.42 MB)
 (PDF)
Printer Friendly Español (PDF)
Approvals and Testing
Tested in accordance with ICC-ES AC 38 criteria to meet IBC and IRC requirements for Weather Resistive Barriers.
| PHYSICAL PROPERTIES | |
|---|---|
| PROPERTY | RESULT | 
| Color | Black (top), Black (back) | 
| Thickness | 0.4798 mm (18.889 mil) | 
| Membrane Weight | 364.66 g/m2 (1.20 oz/ft2) | 
| Roll Weight | 55 lbs (25 kg) | 
| Roll Dimensions | 59" x 102' (1.5m x 31.1m) | 
| Roll Coverage | 500 sq. ft. (46.6 sq. m.) gross | 
| Skid | 1 Roll | 
| Primer | No Primer Required | 
| VOCs | None | 
| Exposure Before Permenant Cladding | 12 months | 
| Minimum Application Temperature | 20°F (-6°C) | 
| Service Temperature | minus 40°F (-40°C) - 225°F (107°C) | 
| Warranty | 20 year material warranty | 
| TESTING DATA | ||
|---|---|---|
| PROPERTY | STANDARD | RESULT | 
| Strength | ||
| Dry Tensile Strength ≥ 20 lbf/in  | 
ASTM D828 Standard Test Method for Tensile Properties of Paper and Paperboard Using Constant-Rate-of-Elongation Apparatus | 6.6 N/mm (37.3 ibf) | 
| Dry Breaking Force (Grab method) MD ≥40 XMD ≥35  | 
ASTM D5034 Standard Test Method for Breaking Strength and Elongation of Textile Fabrics (Grab Test) | MD – 529 N (119 lbf) XMD – 427 N (96 lbf)  | 
| Cold Mandrel Bend Test | AC38 Section 3.3.4 | Warp (Machine) Direction - No cracking Filling (Cross) Direction - No cracking  | 
| Weathering Tests | AC38 Section 4.1.2 UV Exposure AC38 Section 4.1.3 Accelerated Aging  | 
UV - No visual change UV & Accelerated - visibly lighter, no visible deterioration  | 
| Water Vapor Transmittance | ||
| Water Vapor Transmission Desiccant Method  | 
ASTM E96 A 24.4 °C (76.0 °F) 50%RH Standard Test Methods for Water Vapor Transmission of Materials (dry method) | 28.058 Perm(grain/h•ft2•inchHg) 1605 ng/Pa•s•m2  | 
| Water Vapor Transmission Water Method  | 
ASTM E96 B 24.4 °C (76.0 °F) 50%RH Standard Test Methods for Water Vapor Transmission of Materials (wet method) | 63.481 Perm (grain/h•ft2•inchHg) 3632 ng/ 2Pa•s•m2  | 
| Water Vapor Transmission Rate Dynamic Relative Humidity Measurement  | 
ASTM E398 Standard Test Method for Water Vapor Transmission Rate of Sheet Materials Using Dynamic Relative Humidity Measurement | 65.52 Perm (grain/h•ft2•inchHg) 3748 ng/Pa•s•m2 (23°C 50%RH)  | 
| Adhesion Testing | ||
| Adhesion to backing | ASTM D3330 method B | Pass | 
| Peel Adhesion 90° Peel Adhesion, 24 hours  | 
AAMA 711 Section 5.3  | 
Pass | 
| Accelerated Aging and UV Exposure 90° Peel Adhesion, 24 hours | AAMA 711 Section 5.4  | 
Pass | 
| Elevated temperature (122°F (50°C) for 7 days) 90° Peel Adhesion, 24 hours | AAMA 711 Section 5.5  | 
Pass | 
| Thermal Cycling Peel Adhesion 90° Peel Adhesion, 24 hours | AAMA 711 Section 5.6  | 
Pass | 
| Resistance to Peeling from itself 90° Peel Adhesion 24 hours | 
 AAMA 711  | 
Plywood: No peeling, buckling or ripping DensGlas Gold: No peeling, buckling or ripping Concrete: No peeling, buckling or ripping CMU: No peeling, buckling or ripping  | 
| Air Resistance Testing | ||
| Air Permeance | ASTM E2178 @75 Pa Standard Test Method for Air Permeance of Building Materials | 
 0.0001 L/s•m2 @ 75 Pa (0.0000 cfm/ft2 @ 1.57 psf)  | 
| Air Barrier | ASTM E2357 Standard Test Method for Determining Air Leakage of Air Barrier Assemblies | 
 <0.01 L/s•m2 @ 75 Pa (<0.002 cfm/ft2 @ 1.57 psf)  | 
| Air Barrier | ASTM E283 Standard Test Method for Determining Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors Under Specified Pressure Differences Across the Specimen | 
 <0.01 L/s•m2 @ 75 Pa (<0.01 cfm/ft2 @ 1.57 psf)  | 
| Water Reistance Testing | ||
| Nail Sealability | ASTM D1970/ section 7.9 Standard Specification for Self-Adhering Polymer Modified Bituminous Sheet Materials Used as Steep Roofing Underlayment for Ice Dam Protection | Pass - Review Fastener Penetrations Technical Bulletin | 
| Water Resistance (Boat Test) | ASTM D779 Standard Test Method for Water Resistance of Paper, Paperboard, and Other Sheet Materials by the Dry Indicator Method (Withdrawn 2011) | Control - No leakage Weathered - No Leakage  | 
| Water Resistance (Control after Weathering) | AATCC 127 Hydrostatic pressure test (550 mm water column for 5 hours), American Association of Textile Chemists and Colorists | Control - No leakage Weathered - No Leakage  | 
| Fire Testing | ||
| Flame Spread Smoke Developed  | 
ASTM E84 Standard Test Method for Surface Burning Characteristics of Building Materials | Flame Spread 0 Smoke Developed 75  | 
| NFPA 285 Compliant | Standard Fire Test Method for Evaluation of Fire Propagation Characteristics of Exterior Non-Load-Bearing Wall Assemblies Containing Combustible Components | View over 50 compliant assemblies with various manufacturers here or Contact VaproShield Technical Team, 1-866-731-7663 opt. 5 | 
| Cone Calorimeter Testing Data | ASTM E1354 Standard Test Method for Heat and Visible Smoke Release Rates for Materials and Products Using an Oxygen Consumption Calorimeter | Time to Ignition: 6 sec Flame Duration: 64 sec Avg. Effective Heat of Combustion: 5.1 MJ/kg Avg. HRR at 60 sec: 62 kW/m2 Avg. HRR at 180 sec: 0 Peak HRR: 98 kW/m2 Time of Peak: 36 sec Total HRR/A: 4.0 MJ/m2  | 
| CANADIAN STANDARDS | ||
| Multiple | CAN/ULC-S742-11 – Sheathing Membrane, Breather Type | PASS | 
Contact VaproShield Technical Team to learn more about NFPA compliance and testing.
  ![]()  | 
  ![]()  | 
    
            
						
 